Skip to content
David Bennett, Ph.D.

MRI that shows if a drug works. Physics that finally clicks.

Imaging scientist and physics teacher, open to roles, consulting, teaching and talks.

Magnetization relaxing after a 90 degree pulse. Drag to rotate.

20+ yrsin MRI, from research magnets to Phase 3 trials
9.4Tfrom clinical scanners up to research magnets
Phase 3led MRI as a co-primary endpoint
1994the year I started teaching, and never stopped
Portrait of David Bennett
David Bennett, Ph.D.

I started as an engineer, became an MRI physicist, and never stopped teaching. Today I help drug developers decide what an image should measure, and help students see what the equations mean.

What I offer

Full-time or consulting

Imaging endpoints that hold up to regulators

Biomarker and endpoint strategy for Phase 1 to 3 trials, central read charters, imaging CRO oversight and FDA briefing documents. I know the scanner from the coil up, so the science and the logistics agree.

Discuss a role or project

Teaching

Teaching that swaps memorizing for experimenting

College physics, a graduate MRI course I designed from scratch, high school robotics and board exam tutoring, now backed by simulators and AI tools I build myself.

Discuss a course

Talks and workshops

MRI explained so anyone can follow

Talks and workshops on MRI physics, imaging in drug development, and teaching with simulation and AI, shaped for your audience, from students to clinical teams.

Book a talk

Work that moved trials forward

Six projects, from the regulatory strategy behind a Phase 3 endpoint down to the hardware inside the scanner.

  • Takeda, 2020 to 2024

    MRI as a co-primary endpoint in Phase 3

    Led imaging strategy for a cell therapy program in perianal fistulizing Crohn's disease, where the MRI-based central read was a co-primary endpoint.

  • AstraZeneca, 2025

    An FDA briefing document for a rare liver disease

    Wrote the briefing document proposing MR elastography and gadoxetate-enhanced MRI as imaging endpoints for an early-stage primary sclerosing cholangitis study.

  • Parexel, 2014 to 2020

    Oncology imaging lead across dozens of global trials

    Put RECIST 1.1, Lugano and PCWG2 response criteria into practice across multi-center trials, and wrote the review charters and CT, MRI and PET/CT acquisition guidelines behind them.

  • Takeda, 2020 to 2024

    Validating AI readouts and new PET tracers

    Took part in validating an AI-assisted imaging algorithm for regulatory-grade IBD readouts, and co-led collaborations validating PET radiotracers in liver fibrosis and fibrostenotic Crohn's disease.

  • Aurora Imaging, 2008 to 2010

    Systems engineering for a dedicated breast MRI scanner

    RF and gradient hardware and software integration, performance verification, and breast PET-MRI detector integration with Brookhaven National Laboratory.

  • Pfizer, 2010 to 2012

    Preclinical cardiac MRI and spectroscopy at 7 T

    Designed and validated cardiac MRI and MR spectroscopy protocols, and proposed in vivo liver lipid spectroscopy as a first-in-human clinical endpoint.

I use simulation and AI to make physics click

Students learn faster when they can change something and watch what happens. So I build free simulators that run in any browser, some with AI-powered explanations built in.

mrimastery.com

MRI Mastery Simulators

MRI physics you can play with, from a single spin to a finished image. Built for technologists, students and anyone facing the boards.

  • Bloch simulator in 3D
  • K-space explorer
  • Signal processing
  • Coil fields and RF excitation
  • Coil tuning and matching
  • Contrast simulator
  • Head phantom

Early release, for learning only and not for clinical use.

Open MRI Mastery

physicslabbench.com

Interactive Physics Lab

Predict, test, explain. Small experiments that turn introductory physics into something students do, not something they memorize.

  • Newton's laws
  • Circular motion
  • Drag and damped springs
  • Lab bench with uncertainty
  • Momentum, coming soon
  • Work and energy, coming soon
  • Electromagnetism, in development

No account and nothing to install.

Open the Physics Lab

Thirty years on two tracks

Science and engineering on one side, teaching on the other. They have always run together.

Science and engineeringTeaching
1994to 1997
Teaching

Peer tutor

UMass Lowell

Tutored calculus and engineering physics all the way through a B.S. in electrical engineering.

1997to 2002, approx.
Science and engineering

Software and systems engineer

MITRE, Goodrich

Programmed embedded and real-time systems in C, assembly and MATLAB while earning an M.S. in electrical engineering part-time.

2002to 2007
Science and engineering

Ph.D., Biomedical Engineering

Worcester Polytechnic Institute

Moved into MR physics. Dissertation on blood-brain barrier disruption detected by manganese-enhanced MRI.

2002to 2007
Teaching

Graduate teaching assistant

Worcester Polytechnic Institute

Taught in the biomedical engineering department throughout the Ph.D.

2007to 2008
Science and engineering

Postdoctoral fellow, and founder

McLean Hospital / Harvard Medical School

Managed the installation of a 9.4 T preclinical scanner and ran clinical spectroscopy and preclinical imaging for psychiatric biomarkers, while founding and running a small-animal RF coil company.

2008to 2010
Science and engineering

MRI physicist and systems engineer

Aurora Imaging Technology

Hardware and software integration for a dedicated breast MRI scanner, plus PET-MRI detector work with Brookhaven National Laboratory.

2010to 2012
Science and engineering

Senior Scientist

Pfizer

Cardiac MRI and spectroscopy at 7 T. Proposed liver lipid spectroscopy as a first-in-human endpoint.

2012to 2014
Science and engineering

MRI research engineer and lab manager

Beth Israel Deaconess / Harvard

Designed and ran preclinical studies on 4.7 T, 8.5 T and 9.4 T systems.

2012to 2018
Teaching

Adjunct Professor

University of Massachusetts Lowell

Created and taught an original online graduate course in MRI physics, and taught the graduate biomedical research ethics course, alongside a full-time industry role.

2013
Teaching

Invited lecturer, MRI physics

Dartmouth College

Guest lecture on core MRI physics for an interdisciplinary graduate audience.

2014to 2020
Science and engineering

Associate Director, Medical Imaging

Parexel (now Perceptive)

Oncology imaging lead across dozens of global multi-center trials.

2020to 2024
Science and engineering

Associate Scientific Director, Clinical Imaging

Takeda

Led the imaging strategy behind an MRI co-primary endpoint in a Phase 3 program.

2024to 2025
Teaching

Engineering and robotics teacher

Methuen High School

Five sections a term. Students built robots that solved an unseen maze on their own.

2025
Science and engineering

Director, Clinical Imaging

AstraZeneca

Wrote an FDA briefing document proposing new MRI endpoints for a rare liver disease.

2025to 2026
Teaching

Tutor and simulator builder

Independent

Tutored MRI board candidates, completed an MIT certificate in applied AI, and built two free simulator sites.

2026to now
Teaching

Adjunct, General Physics

Merrimack College

Teaching General Physics I, algebra-based, with interactive simulations built for the course.

Next stop: your team, your classroom, or your stage.

Ph.D., Biomedical EngineeringWorcester Polytechnic Institute. Dissertation: Osmotic- and Stroke-Induced Blood-Brain Barrier Disruption Detected by Manganese-Enhanced MRI.
M.S., Electrical EngineeringUniversity of Massachusetts Lowell, earned part-time while working as a software engineer.
B.S., Electrical Engineering, cum laudeUniversity of Massachusetts Lowell.
Certificate, Applied AI and Data ScienceMassachusetts Institute of Technology, 2026.

Peer-reviewed work

  • European Radiology, 2024
    Volumetric measurement of terminal ileal Crohn's disease by magnetic resonance enterography: a feasibility study.Kumar S., Bhagwanani A., Hameed M., Rao N., Parry T., Rahman S., Bennett D., et al. 35(1):117–126.
  • PLOS ONE, 2016
    Neuregulin-1 administration protocols sufficient for stimulating cardiac regeneration in young mice do not induce somatic, organ, or neoplastic growth.Ganapathy B., Polizzotti B., Bennett D., et al. 11(5):e0155456.
  • Science Translational Medicine, 2015
    Neuregulin stimulation of cardiomyocyte regeneration in mice and human myocardium reveals a therapeutic window.Polizzotti B.D., Ganapathy B., Walsh S., Choudhury S., Ammanamanchi N., Bennett D.G., et al. 7:281ra45.
  • Nature Communications, 2014
    Image-guided radiotherapy platform using single nodule conditional lung cancer mouse models.Herter-Sprie G.S., Korideck H., Christensen C.L., et al. 5:5870.
  • Chembiochem, 2007
    A paramagnetic contrast agent for detecting tyrosinase activity.Querol M., Bennett D.G., Sotak C.H., Bogdanov A.A. Jr. 8(14):1637–41.

Hire me, book me, or just ask.

Tell me what you need: an imaging endpoint, a physics course, or a talk.

dgbenn@gmail.com
© 2026 David Bennett, Ph.D.Methuen, Massachusetts